Protection and inspection of disposable surgical packs

During the operation, the disposable medical surgical pack should be placed in the designated position so that it can be accessed at any time and prevent a mutual collision.

During the operation, the surgeon should place the disposable medical surgical pack in the designated position so that it can be accessed at any time and prevent a mutual collision. Especially sharp tools should be used with care. For example, ophthalmic scissors should not be used to cut thick and tough tissue, gauze rolls, cotton rolls, etc.

Disposable medical surgical packs for long-term storage should be coated with a layer of petroleum jelly. Frequently used instruments are wiped with liquid paraffin after the blood has been cleaned to prevent rusting. Sharp and blunt objects should be stored separately. Sharp instruments cannot be autoclaved and boiled. Only in very urgent cases should it be sterilized by boiling for a short time (3 minutes) so as not to damage the sharp edges.

surgical pack

Before sterilizing disposable medical surgical packs, operating room personnel should carefully check that the surgical instruments are adequate and suitable. For example, if the tips of the scissors close tightly, the two strands should be opened and placed in a sterilization tray for sterilization. The sharpness of the blade can be checked with a magnifying glass or a drum tester with straight knives and pistol knives, and the tip of the knife is wrapped with cotton before sterilization. For all kinds of trephine drills, special attention should be paid to cleaning the oil stains in the drill barrel. Disinfect after rubbing. For each trephine, the number of times it was used should be recorded for easy selection during surgery. The elasticity of the two strands of the iris forceps should also be checked.

Most disposable medical surgical packs are sterilized by soaking in a 1/1000 New Germe solution containing 0.5% sodium nitrite. Soak for 30 minutes to achieve the purpose of disinfection, and add sodium nitrite to prevent rust. Sterilization trays that frequently soak instruments should be autoclaved every 2 to 4 weeks. and replace it with a new disinfectant.

The above is about the protection and inspection of the surgical pack, I hope it will be helpful to everyone. As a Chinese surgical pack company, Innovision Medical provides high-quality surgical packs. If you are interested in surgical packs, please pay attention to our website.

 

Comments